Ranges: | Autoranging 0-200 ppm (Analogue ranges 0-50 ppb to 0-200 ppm) |
Concentration display: | User selectable mg/m3, μg/m3, ppm, ppb, ppt |
Noise: | < 0.02 ppm or 0.2% of concentration reading whichever is greater |
Lower detectable limit: | < 0.04 ppm or 0.2% of concentration whichever is greater |
Linearity: | < 1% of full scale (0-50 ppm) |
Precision: | 0.1 ppm or 0.1% of reading whichever is greater |
Zero drift: | 24 hours: < 0.5 ppm; 7 days: < 0.1 ppm |
Span drift: | 7 days: < 0.5% of reading |
Response time: | 7 days: < 0.5% of reading |
Response time: | 60 seconds to 95% |
STP reference: | 0 °C, 20 °C, 25 °C at 101.3 kpa |
Sample flow rate: | 1000 cc/min |
Temperature range: | 0 – 40 °C |
Power: | 198-264 VAC 47-63 Hz 255 VA (max startup), 180 VA (nominal) |
Dimensions: | 3.5 RU, 429 x 175 x 638 mm |
Weight: | 17.8 kg |
Communications: | USB, RS 232, TCP/IP, Bluetooth |
Data logging: | Removable USB flash memory drive that stores instantaneous data as well as average data from 1 minute upto 24 hours. 1 minute data can be stored for 10 years |
Additional Information:
Specifications:
Range: | Autoranging 0-20ppm (Analogue ranges 0-50 ppb to 0-20 ppm) |
Noise: | User selectable mg/m3, μg/m3, ppm, ppb, ppt |
Concentration display: | < 0.15 ppb |
Lower detectable limit: | < 0.3 ppb or 0.2% of concentration whichever is greater |
Linearity: | < 1% of full scale |
Precision: | 0.5 ppb |
Zero drift: | 24 hours: < 0.5 ppb; 7 days: < 0.5 ppb |
Span drift: | 7 days: < 0.5% of reading |
Response time: | 60 seconds to 95% |
STP reference: | 0 °C, 20 °C, 25 °C at 101.3 kpa |
Sample flow rate: | 725 cc/min |
Temperature range: | 0 – 40 °C |
Power: | 99-132 VAC, 198-264 VAC 47-63 Hz 255VA (max startup), 180 VA (nominal) |
Dimensions: | 3.5 RU, 429 x 175 x 638 mm |
Weight: | 18.1kg |
Additional Information:
Ranges: | Autoranging 0-20ppm (Analogue ranges 0-50 ppb to 0-20 ppm) |
Concentration display: | User selectable mg/m3, μg/m3, ppm, ppb, ppt |
Noise: | < 0.2 ppb |
Lower detectable limit: | < 0.4 ppb or 0.5% of reading whichever is greater |
Linearity: | < 1% of full scale |
Precision: | 0.4 ppb or 0.5% of reading whichever is greater |
Zero drift: | 24 hours: < 0.4 ppb |
Span drift: | 7 days: < 1% of reading |
STP reference: | 0°C, 20°C, 25°C at 101.3 kPa |
Sample flow rate: | 680 cc/min (total for 2 channels) |
Temperature range: | 0 – 40 °C |
Power: | 99-132 VAC, 198-264 VAC 47-63 Hz |
Dimensions: | 3.5 RU, 429 x 175 x 638 mm |
Weight: | 21.85 kg |
Communications: | USB, RS 232, TCP/IP, Bluetooth |
Additional Information:
Additional Information: